Close

Type II

Pure water

The tasks in the laboratory determine the choice of the appropriate Omnia system. Pure water is used for the complete basic supply is used in the laboratory. Whether for the operation of autoclaves and dishwashers, media preparation and production of buffer solutions, or feeding of ultrapure water systems.

OmniaTap II

The compact for pure water.
For H2O pure type II.

 

OmniaTap II is the compact system with integrated reverse osmosis and deionization for type II pure water. It can be connected directly to a drinking water pipe. The flexible dispenser allows a very practical withdrawal of water at the push of a button via the digital control of the dispenser. The removal takes place at the push of a button via the digital control of the dispenser.

 

The available choice of storage tanks (10, 30 or 60 liters) with recirculation keeps the quality permanently at a high level. An optional pressure output on the pure water tank can also be used to supply downstream end devices.

  • Safe pure water quality ASTM II
  • TapWater-Set – direct tap water connection
  • OptiFilltouch Dispenser is standard
  • Simple and economical filter change
  • Clear control with graphic display
  • Leakage sensor is standard

 

OmniaTap II 6 / 6 UVOmniaTap II 12 / 12 UVOmniaTap II 20 / 20 UV
Pure water performance at 15 °C [l/h]61220
Conductivity* [µS/cm]0.1 up to  10.1 up to  10.1 up to 1
Resistance* [MΩ x cm]10 up to 110 up to 110 up to 1
TOC value* [ppb]< 30< 30< 30
Silicate removal* [%]> 99> 99> 99
Dispensing performance [l/min.]up to 2up to 2up to 2
Individually adjustable dispensing volume [liters]0.05 up to 250.05 up to 250.05 up to 25
Particles** > 0.2 µm [1/ml]< 1< 1< 1
Bacteria** [CFU/ml]< 0.01< 0.01< 0.01
Pressure outlet pure water tank100 l/h – 2 bar100 l/h – 2 bar100 l/h – 2 bar
UV desinfection 254 nm– / yes– / yes– / yes
* The values given are typical and may vary depending on the quality of the feed water.** With sterile filter capsule 0.2 µm

OmniaTap II 6 / 6 UVOmniaTap II 12 / 12 UVOmniaTap II 20 / 20 UV
Tap water according to DIN 2000
Feedwater pressure [bar]1 up to 61 up to 61 up to 6
Conductivity at 25 °C [µS/cm]< 2000*< 2000*< 2000*
Colloid index SDI< 5**< 5**< 5**
Dissolved CO2 [ppm]< 30< 30< 30
Free chlorine [ppm]< 0.1< 0.1< 0.1
TOC-value [ppm]< 2< 2< 2
Hardness [as CaCO3< 300< 300< 300
Iron/manganese [mg/l]< 0.05< 0.05< 0.05
Silica [ppm]< 30< 30< 30
pH range4 up to 104 up to 104 up to 10
* Feed water with high conductivity can reduce the service life of the cartridges and increase the conductivity of type III water. If the conductivity is between 800 and 2000 µS/cm, we recommend using a water softener.** With an SDI/FI between 3 and 5, pre-treatment must be used

OmniaTap II 6 / 6 UVOmniaTap II 12 / 12 UVOmniaTap II 20 / 20 UV
Feedwater connectionR 3/4″R 3/4″R 3/4″
Electrical connection [Volt/Hz]90 – 240/50 – 6090 – 240/50 – 6090 – 240/50 – 60
Connected load [kW]0.10.10.1
Ambient temperature [°C]4 up to 400.10.1
[Recommendation: 10 up to 25]4 up to 40+ 2 up to 35+ 2 up to 35
[Recommendation: 10 up to 25]4 up to 40390 x 720 x 615390 x 720 x 615
[Recommendation: 10 up to 25]202121
Dimensions Tower without tank* [W x H x D mm]390 x 720 x 525390 x 720 x 525390 x 720 x 525
Dimensions Tower with 10-liter tank* [W x H x D mm]390 x 720 x 615390 x 720 x 615390 x 720 x 615
Weight without 10-liter tank [kg]171818
Weight with 10-liter tank [kg]202122
* With OptiFill Dispenser

Article no.System type*Typical applications
18200214OmniaTap II 6Buffer and media preparation
18200217OmniaTap II 12Buffer and media preparation
18200220OmniaTap II 20Buffer and media preparation
18200215OmniaTap II 6 UVBuffer and media preparation
18200218OmniaTap II 12 UVBuffer and media preparation
18200221OmniaTap II 20 UVBuffer and media preparation
* RO cartridge, pure water cartridge and sterile filter capsule 0.2 μm included.** The Omnia production unit can either be installed on a bench or on a wall.

Articles no.Accessories
19200020Pre-treatment unit 5 µm + hardness stabilization
19200022Pre-treatment unit 5 µm + activated carbon
19200300Wall mount Omnia
19200056Disinfection cartridge Omnia
19200057Disinfectant Omnia – 1 pcs./Pkg.
19200091Disinfection kit Omnia (cartridge + 1 pcs. disinfectant)
19200062Data printer


Pure water tanks for OmniaTap devices
Article no. **Volume (Liters)MaterialDimensions*
(W x H x D mm)
Weight
dry (kg)
1650001010 lPEDocking tank2.7
1650003130 lPE338 x 568 x 4026.5
1650006160 lPE338 x 778 x 4028
* Without aeration filter** With level sensor, sterile overflow, ventilation filter + CO2 absorber
Pure water tank with integrated booster pump
Artikel no.**Pump capacity (l/h-bar)Weight dry (kg)
16500032100-210
16500062100-211
** With level sensor, sterile overflow, ventilation filter + CO2 absorber
Accessoires
Article no.Accessoires
19200050UV tank disinfection unit Omnia 254 – 16 watts
28000084Tank removal set for OmniaTap 7-liter docking tank
19501500Wall mount for pure water tank 30/60 l
16580000External pump station 100 l/h – 2 bar
16561201External pump station 2000 l/h – 3.5 bar

OmniaLabED

The efficient for pure water.
For H2O pure type II.



OmniaLabED is the efficient solution when high-quality pure water is required for complete type II laboratory supply.

The system meets international water standards such as ASTM, ISO 3696, CLRW (CLSI) and is economically maximized by combining it with continuously self-regenerating electro-deionization. In addition, the OmniaLabED system holds 100 liters of pure water in a storage tank with quality recirculation to supply subsequent laboratory equipment.

OmniaLabED is predestined for the supply of autoclaves, laboratory dishwashers and ultrapure water systems.

  • OptiFilltouch dispenser is standard
  • Continuous residual salts removal by electro-deionization
  • 100 litre storage tank with recirculation and pressure outlet
  • Tank volume display in percent
  • Tank volume can be modularly increased
  • Simple, cost-effective filter replacement
  • Leakage sensor is standard

OmniaLabED 20OmniaLabED 40
Pure water type II
Pure water performance l/h at 15 °C2040
Conductivity [μS/cm]0.1 up to 10.1 up to 1
Resistance [MΩ x cm]10 up to 110 up to 1
TOC value* [ppb]< 30< 30
Silicate removal* [%]> 99> 99
Dispensing performance [l/min.]up to 2up to 2
Individually adjustable dispensing volume [liters]0.05 up to 250.05 up to 25
Particles** > 0.2 µm [1/ml]< 1< 1
Bacteria** [CFU/ml]< 0.01< 0.01
Pressure outlet pure water tank100 l/h – 2 bar100 l/h – 2 bar
* Depending on the quality of the feed water** With sterile filter capsule 0.2 µm

OmniaLabED 20OmniaLabED 40
Softened water according to DIN 2000
Feedwater pressure [bar]1 up to 61 up to 6
Conductivity at 25 °C [µS/cm]< 2000*< 2000*
Colloid index SDI< 5**< 5**
Dissolved CO2 [ppm]< 30< 30
Free chlorine [ppm]< 0.1< 0.1
TOC-value [ppm]< 2< 2
Hardness [as CaCO3] [ppm]< 1< 1
Iron/manganese [mg/l]< 0.05< 0.05
Silica [ppm]< 30< 30
pH range4 up to 104 up to 10
* Feed water with high conductivity can reduce the service life of the cartridges and increase the conductivity of type III water.** With an SDI/FI between 3 and 5, pre-treatment must be used

OmniaLabED 20OmniaLabED 40
Feedwater connectionR 3/4″R 3/4″
Electrical connection [Volt/Hz]90–240/50–6090–240/50–60
Connected load [kW]0.250.25
Ambient temperature [°C]4 up to 40 [Recommendation: 10 up to 25]4 up to 40 [Recommendation: 10 up to 25]
Dimensions Tower* [W x H x D mm]511 x 1520 x 575511 x 1520 x 575
Dimensions Base cabinet tank [W x H x D mm]511 x 800 x 575511 x 800 x 575
Weight [kg]4141
* With OptiFill Dispenser

System type*Typical applications
18710021OmniaLabED 20Feedwater for autoclaves, laboratory washers and
ultrapure water systems
18710041OmniaLabED 40Feedwater for autoclaves, laboratory washers and
ultrapure water systems
* RO cartridge, sterile filter capsule 0.2 μm, sterile overflow and sterile vent filter + CO2 absorber included.

Article no.Accessories
25015000System separator ST 20 FK4 Compact
16127200Single softener WEA 32 Compact
19200022Pre-treatment unit 5 µm + activated carbon
19200056Disinfection cartridge Omnia
19200057Disinfectant Omnia – 1 pcs./Pkg.
19200058Disinfection kit Omnia (cartridge + 1 pcs. disinfectant)
19200050UV tank disinfection unit Omnia 254 – 16 watts
19200100Docking tank volume 100 liters
16561201External pump station 2 m³/h – 3.5 bar
19200062Data printer

OmniaLabUP

The reliable one for pure water.
For H2O pure type II.

 

If high-quality pure water is required for the complete laboratory supply, the OmniaLabUP is the right system. It meets international water standards such as ASTM, ISO 3696 and CLRW (CLSI).

 

In addition, the OmniaLabUP-System holds 100 liters of pure water type II in a storage tank with quality recirculation ready for withdrawal. OmniaLabUP supplies autoclaves, laboratory dishwashers and ultrapure water systems.

  • OptiFill Dispenser is standard
  • 100 l tank with quality recirculation and pressure outlet
  • Tank volume display in percent
  • Tank volume can be modularly increased
  • Simple, cost-effective filter replacement
  • Leakage sensor is standard

OmniaLabUP 20OmniaLabUP 40
Pure water values type II
Pure water performance l/h at 15 °C2040
Conductivity [μS/cm]0.067 up to 0.10.067 up to 0.1
Resistance [MΩ x cm]15 up to 1015 up to 10
Dispensing performance [l/min.]up to 2up to 2
Particles** > 0.2 µm [1/ml]< 1< 1
Bacteria** [CFU/ml]< 0.01< 0.01
Pressure outlet pure water tank100 l/h – 2 bar100 l/h – 2 bar
** With sterile filter capsule 0.2 µm

OmniaLabUP 20OmniaLabUP 40
Softened or hardness-stabilized water according to DIN 2000
Feedwater pressure [bar]1 up to 61 up to 6
Conductivity at 25 °C [µS/cm]< 2000*< 2000*
Colloid index SDI< 5**< 5**
Dissolved CO2 [ppm]< 30< 30
Free chlorine [ppm]< 0.1< 0.1
TOC-value [ppm]< 2< 2
Hardness [as CaCO3] [ppm]< 300< 300
Iron/manganese [mg/l]< 0.05< 0.05
Silica [ppm]< 30< 30
pH range4 up to 104 up to 10
* Feed water with high conductivity can reduce the service life of the cartridges and increase the conductivity of type III water. If the conductivity is between 800 and 2000 µS/cm, we recommend using a water softener.** With an SDI/FI between 3 and 5, pre-treatment must be used

OmniaLabUP 20OmniaLabUP 40
Feedwater connectionR 3/4″R 3/4″
Electrical connection [Volt/Hz]90–240/50–6090–240/50–60
Connected load [kW]0.10.1
Ambient temperature [°C]4 up to 40 [Recommendation: 10 up to 25]4 up to 40 [Recommendation: 10 up to 25]
Dimensions Tower* [W x H x D mm]511 x 1520 x 575511 x 1520 x 575
Dimensions Base cabinet tank [W x H x D mm]511 x 800 x 575511 x 800 x 575
Weight [kg]4040
* With OptiFill dispenser

Article no.System type*Typical applications
18600020OmniaLabUP 20Feedwater for autoclaves, laboratory washers and ultrapure water systems
18600040OmniaLabUP 40Feedwater for autoclaves, laboratory washers and ultrapure water systems
* RO cartridge, pure water cartridge, sterile filter capsule 0.2 μm, sterile overflow and sterile vent filter + CO2 absorber included.

Article no.Accessories
19200020Pre-treatment unit 5 µm + hardness stabilization
19200022Pre-treatment unit 5 µm + activated carbon
19200056Disinfection cartridge Omnia
19200057Disinfectant Omnia – 1 pcs./Pkg.
19200058Disinfection kit Omnia (cartridge + 1 pcs. disinfectant)
19200050UV tank disinfection unit Omnia 254 – 16 watts
19200054UV Flow-through disinfection 254
19200100Docking tank volume 100 liters
16561201External pump station 2 m³/h – 3.5 bar
19200500Volume dosing Omnia